Thank you for purchasing and using GSM LCD touch screen wireless home alarm system. This is a Hi-tech household security product. It will make your life safer and colorful.
A. Product components: This product is composed of alarm host, basic accessories and optional accessories.
Alarm Host | Wireless Optional Accessories |
GSM LCD Alarm Host |
remote, wireless intelligent door sensor(or wireless door sensor) wireless wide-angle PIR sensor, wireless indoor siren with sound and flash, gas alarm, smoke alarm, wireless outdoor siren, doorbell button |
Table 1: Product components
1. Touch keypad; LCD displays Date, Day of the week, Time, and current Armed Status
2. Supported Languages: Simplified Chinese\ Traditional Chinese\ English\ German\ French\ and more to meet different market needs..
3. GSM3/4 Band Net trasmission,phone audible alarming and SMS alarming
4. 29 wireless zones (Each zone supports up to 4 sensors) and 2 dedicated zones for remotes (Supports up to 4 remotes or wireless keypads per zone). Sipports 8 more wired zones(Optional).
5. Can preset up to 5 phone numbers and dial in sequence.
6. Intelligent logic analysis technology, corresponding zone number and sensor name can be displayed.
7. Record up to a 10 second greeting for the auto-dialer, Then play the greeting back.
8. Arm\ Disarm the system by 5 ways: SMS, Main Host(Keypad), Wireless Keypad, Keychain Remotes, or even remotely by phones. (PSTN alarm don’t support SMS)
9. Available in AC\DC with Low-voltage Indicators
10. Learning sensors to alarm host, very easy operation.
11. Non-volatile chip, information stored automatically when off power.
12. Check door\window status automatically (This is when the system is disarmed only, if a door is opened, it will sound fast “bi bi bi”)
13. Support wireless “ding-dong” doorbell function (Optional)
14. Support CID uploading to CMS(Center monitoring Station) , can user our GSM CID connector to have this function.
15. Disconnection alarm, auto priority to occupy the telephone and monitoring function to hear what is happening.
16. Built-in Li-Ion backup battery, it will alert when low power or without external power supply.
17. Store up to 100 alarm records and 100 arm\disarm records
1. Specifications:
2. Zone types and definitions
Perimeter zone: Detecting the space like doors, windows, etc., generally use wireless door magnet sensors and wireless curtain PIR sensors
Motion zone: Detecting the space like living room, aisles and bedrooms, etc., generally use wireless wide-angle PIR sensors.
Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue, gas leakage and
fire alarm, etc., this zone keep 24-hour monitoring status automatically. Generally use panic button, wireless gas sensors and
wireless smoke sensors.
3. Modes of arming
“Away Arm” mode:Once any detectors in perimeter zones or motion zones get triggered, the host will alarm immediately and meantime dial “#” automatically.
“Home Arm” mode:Once any detectors in perimeter zones get triggered, the host will alarm immediately and meantime dial “#” automatically. It will not alarm after any detectors in the motion zone are triggered.
Common Problems and Solutions
Symptoms of Faults | Possible Cause | Solution |
The alarm host can’t fully record |
Did not keep pressing the record all the time while recording |
Keep pressing the record all the time while recording |
Repeatedly receiving the alarm telephone |
Fail to operate according to the operation instruction of the telephone alarm |
Follow the below instructions after answering the alarm phone calls and hearing the recorded message: (See Point 6 of “How to operate the Alarm Host?”) |
Can’t receive alarm sms or can’t receive sms reply after made arm or disarm operation by sms |
1. SIM card is not insert properly 2. GSM signal is not good enough |
1. Insert SIM card properly 2. Adjust alarm host’s installation position till the signal status shows “OK” |
The host does not alarm after the detector is triggered in arm state |
1. Caused by the functions of arm mode (Armed Away and Armed Home); 2. Have already setup time for Entry Delay or Exit Delay |
1.“Armed Away” mode: alarm goes off when any sensor is triggered; 2. “Armed Home” mode: alarm goes off when any sensor in Perimeter zone is triggered and it won’t alarm when any sensor in Motion zone is triggered 3. Program to adjust the time for Entry Delay or Exit Delay |
The PIR sensor doesn’t work |
1. Not properly connected to the power 2. Port of the detector is in the power-down mode. |
1. Open the sensor shells to install the batteries well and slide the power switch to “On”; 2. “5S”: detect once every 5 seconds; “5MIN”: detect once every 5 minutes; |
The detecting distance of PIR sensor gets shorter |
The ambient temperature in the detecting area is too high. |
When the ambient temperature in the detecting area exceeds the human body temperature, the detecting distance will get shorter, it’s normal. |
The host does not alarm after the new added wireless detector is triggered. |
Failed to follow the operation instruction of “Adding and deleting sensors” to add the new wireless sensor |
Follow the operation instruction of “How to program” to activate the new wireless sensor |
The PIR sensor flashes frequently in green. |
Batteries are running out. | Replace with new batteries of the same specification. |
The door sensor’s indicator flashes frequently. |
Batteries are running out. | Replace with new batteries of the same specification. |
The distance of the remote controller gets shorter. |
Batteries are running out. | Replace with new batteries of the same specification. |
Daily Maintenance and Care